ULMEKA · CAL · MM000020040060080100120140160180200220240260280300
Accueil/Catégories d'essais/IP Testing Equipment
Catégorie d'essai

IP Testing Equipment.

Water and dust ingress protection testing per IEC 60529 (IPX, IP5X/6X) and ISO 20653.

/ 01

À propos de cette catégorie.

Overview

IP testing verifies how well an enclosure keeps out solid objects, dust and water — the protection summarised by the two-digit IP (Ingress Protection) rating defined in IEC 60529. The first digit rates protection against solids and dust, the second against water, so a rating such as IP65 or IP67 tells a user exactly what conditions a product can withstand.

For a manufacturer, an IP rating is often a market requirement and a selling point, which means it has to be proven by test rather than simply declared. IP testing equipment reproduces dust, water and access conditions in a controlled, repeatable way so that a claimed rating can be demonstrated and certified.

What IP Testing Covers

An IP rating bundles together several independent protection checks, each reproduced by a dedicated test:

  • Solid-object and dust ingress — from large objects down to fine dust (the first IP digit, IP1X–IP6X), including full dust-tightness for sealed enclosures.
  • Water ingress — from dripping and spraying through powerful jets to temporary or continuous immersion and high-pressure, high-temperature jets (the second IP digit, IPX1–IPX9K).
  • Access to hazardous parts — verified with standard probes representing a finger, tool or wire, so the enclosure protects users as well as internal components.

Related Standards

IP testing is built on two standards used together: IEC 60529 defines the IP Code itself — the digits, their meaning and the test conditions for each level — while IEC 61032 specifies the standard probes used to verify protection against access and the ingress of solid objects. A complete IP assessment therefore draws on both documents.

Equipment & Configuration

The IP range is covered by several equipment families, each configured to the enclosure size and the IP level being verified:

  • Dust chambers — circulate fine talc dust around the enclosure, with optional vacuum to draw dust toward the sample for the most demanding dust-tight (IP6X) checks.
  • Water ingress rigs — drip boxes, oscillating-tube and spray fixtures, hose and jet nozzles, immersion tanks and high-pressure jets, each matched to the IPX level under test.
  • Test probes — the standardised finger, wire and sphere probes used to confirm access and object protection.

ULMEKA IP Testing Equipment

ULMEKA Mechatronics designs and manufactures the full range of IP testing equipment — dust chambers, water ingress rigs and the standard test probes — configured to the enclosure size and IP level each customer needs. The equipment below covers this category; for a specific IP rating or test configuration, the requirements are confirmed at the proposal stage.

/ 02

Normes associées.

/ 03

16 équipements dans cette catégorie.

IP Probe 41 and 43
Sondes et accessoires
IP Probe 41 and 43
IP Probe 41 and 43 Test Probes 41 and 43 are typically used for testing electrical and electronic devices’ protection
TypeSondes et accessoires
NormesIEC 60529 · IEC 61032
Ouvrir la fiche technique
IP Probu: Test Probe A
Sondes et accessoires
IP Probu: Test Probe A
TypeSondes et accessoires
NormesIEC 60529 · IEC 61032
Ouvrir la fiche technique
IP Test Cabin
Chambres d'essai de pluie
IP Test Cabin
TypeChambres d'essai de pluie
NormesIEC 60529
Ouvrir la fiche technique
IP Test Probe 11
Sondes et accessoires
IP Test Probe 11
IP Test Probe 11 IP Test Probe 11 is designed in accordance with the IEC 61032 standard and is used
TypeSondes et accessoires
NormesIEC 61032 · IEC 60529
Ouvrir la fiche technique
IP Test Probe 12 and 13
Sondes et accessoires
IP Test Probe 12 and 13
TypeSondes et accessoires
NormesIEC 60529 · IEC 61032
Ouvrir la fiche technique
IP Test Probe 18 and 19
Sondes et accessoires
IP Test Probe 18 and 19
IP Test Probe 18 and 19 IP Test Probes 18 and 19 are used to test the protection of electrical
TypeSondes et accessoires
NormesIEC 60529 · IEC 61032
Ouvrir la fiche technique
IP Test Probe 31 and 32
Sondes et accessoires
IP Test Probe 31 and 32
IP Test Probe 31 and 32 IP Test Probes 31 and 32 are used to verify the IP protection ratings
TypeSondes et accessoires
NormesIEC 61032 · IEC 60529
Ouvrir la fiche technique
IP Test Probe B (Jointed Test Finger)
Sondes et accessoires
IP Test Probe B (Jointed Test Finger)
IP Test Probe B (Jointed Test Finger) IP Test Probe B (Jointed Test Finger) is an essential tool used to
TypeSondes et accessoires
NormesIEC 61032 · IEC 60529
Ouvrir la fiche technique
IP Test Probe C and D
Sondes et accessoires
IP Test Probe C and D
IP Test Probe C and D IP Test Probe C and D are essential tools used to validate the design,
TypeSondes et accessoires
NormesIEC 60529 · IEC 61032
Ouvrir la fiche technique
IP Test Room
Chambres walk-in
IP Test Room
IP Test Room and Water Resistance Tests An IP (Ingress Protection) test room is a specialized testing environment used to
TypeChambres walk-in
NormesIEC 60529
Ouvrir la fiche technique
IP5X and IP6X Dust Test Chambers
Chambres d'essai de poussière
IP5X and IP6X Dust Test Chambers
IPX5 – IPX6 Dust Test Cabin According to your needs, we can configure this IP test device along with other IP test devices ( IPX3, IPX4, IPX7, IPX8, IPX9 ). For information and ordering regarding IPX5 – IPX6 Dust Test Cabin ,
TypeChambres d'essai de poussière
NormesIEC 60529
Ouvrir la fiche technique
IPX3 and IPX4 Spray Nozzles
Chambres d'essai de pluie
IPX3 and IPX4 Spray Nozzles
IPX3 and IPX4 Spray Nozzles The IPX3 and IPX4 spray nozzles are used in tests that measure the water resistance
TypeChambres d'essai de pluie
NormesIEC 60529
Ouvrir la fiche technique
IPX3 – IPX4 (Oscillating Tube Tester) – IPX9K Protection Tests
Chambres d'essai de pluie
IPX3 – IPX4 (Oscillating Tube Tester) – IPX9K Protection Tests
IPX3 – IPX4 – IPX9K Protection Tests According to your needs, we can configure this IP test device along with other IP test devices ( IPX5, IPX6, IPX7, IPX8 ). For information and ordering regarding IPX3 – IPX4 (Oscillating Tube Tester) – IPX9K Protection Tests ,
TypeChambres d'essai de pluie
NormesIEC 60529 · ISO 20653
Ouvrir la fiche technique
IPX5 and IPX6 Water Jet Resistance Tests
Chambres d'essai de pluie
IPX5 and IPX6 Water Jet Resistance Tests
IPX5 and IPX6 Water Jet Resistance Tests The IPX5 and IPX6 tests measure the resistance of enclosures to water jets.
TypeChambres d'essai de pluie
NormesIEC 60529
Ouvrir la fiche technique
MIL-STD-810H Rain (Method 506.6) Test Chamber
Chambres d'essai de pluie
MIL-STD-810H Rain (Method 506.6) Test Chamber
A fully automated, mobile MIL-STD-810G/H Method 506.6 rain test chamber — Procedure I (Blowing Rain), II (Exaggerated) and III (Drip), run singly, in pairs (I+II / I+III / II+III) or all three. The test item is placed inside the stainless enclosure.
TypeChambres d'essai de pluie
NormesMIL-STD-810H · IEC 60529
Ouvrir la fiche technique
MIL-STD-810H Method 506.6 walk-in rain test chamber
Chambres walk-in
Mil STD 810H Rain (Method 506.6) Test Room
A MIL-STD-810G/H Method 506.6 walk-in rain test room for large, vehicle-class or drive-in test items — Procedure I (Blowing Rain), II (Exaggerated) and III (Drip), run singly, in pairs (I+II / I+III / II+III) or all three. Built as a fixed installation; sizing is order-specific.
TypeChambres walk-in
NormesMIL-STD-810H · IEC 60529
Ouvrir la fiche technique
Outil associéSélecteur d'indice de protection IP
Au-delà du catalogue

ULMEKA conçoit des systèmes d'essais
selon vos spécifications.

Si votre besoin sort de ce catalogue — dimensions de chambre sur mesure, intégration de normes combinées ou profils d'essais personnalisés — adressez-vous à notre équipe d'ingénierie.