Request Quote
ULMEKA · CAL · MM000020040060080100120140160180200220240260280300
Home/Test Systems/Specialty
Specialty
IEC 61215
Solar Panel Visual Inspection System (IEC 61215-2, MQT 01)
Specialty

Solar Panel Visual Inspection System (IEC 61215-2, MQT 01).

IEC 61215
Industries Served

Controlled-lighting visual inspection station for photovoltaic modules to IEC 61215-2 (MQT 01), with X–Y zoom camera and large-format display.

Standard / methodIEC 61215-2 (MQT 01) visual inspection
Illumination≥ 1000 lux, front + rear, independent control lux
CameraX–Y travel, ≥ 20× optical zoom
Display43" LED
Sample size1.90 × 1.0 m to 2.60 × 1.5 m
Frame thickness5–50 mm
FixturingTool-free, 360° rotation
LampsG13/T8, replaceable

The Solar Panel Visual Inspection System provides the controlled conditions for the visual inspection defined in IEC 61215-2 (MQT 01). It is built to reveal the visual defects a photovoltaic module can develop — cracks, bubbles, delamination, discolouration and similar flaws — both before and after the other qualification tests in the sequence.

The module is illuminated from the front and from behind by independently controlled lighting at no less than 1000 lux, and an operator examines it through a camera that travels on X and Y axes with at least 20× optical zoom. The live image is shown on a 43-inch display, so fine detail across a large module can be inspected without moving the panel.

The sample is held by hand without tools, stays at the chosen angle and can be rotated a full turn; the fixture accepts module frames from 5 mm to 50 mm thick and panel sizes from 1.90 × 1.0 m up to 2.60 × 1.5 m. The aluminium-profile structure and replaceable G13/T8 lamps keep the station serviceable.

ULMEKA designs and manufactures this system. Lighting layout, camera travel and fixturing are built to the module sizes and the applicable standard; the exact configuration is defined during the quotation stage.

/ 01

Standards
& methods.

Specialty
StandardReference
IEC 61215Photovoltaic (PV) Modules — Design Qualification and Type Approval
/ 02

Applications.

  • Photovoltaic (PV) module visual inspection
  • IEC 61215-2 MQT 01 visual inspection
  • PV module crack, delamination and discolouration detection
  • Solar module research and test laboratories
Beyond the catalogue

ULMEKA engineers test systems
to specification.

If your requirement is outside this catalogue — custom chamber sizes, combined-standard integration, or tailored test profiles — talk to our engineering team.

Talk to an engineer
/ 03