IEC 60068-2
Temperature range−72 … +180 °C (on request)
Humidity range10 … 98 %RH
Temperature deviation±0.1 / ±0.5 °C
Humidity deviation±1 / ±3 %RH
Rate of changeHeating ~4 / cooling ~2 °C/min
Heating power~5000 W (temperature) · 500 W (humidity)
Control7" PLC touchscreen; Siemens/Beckhoff software (optional, historical statistics)
Construction (interior / exterior)304 stainless steel / electrostatic powder coat
Volume / loadOn request

Climatic Test Chambers are used to evaluate the performance of products under varying temperature and humidity conditions. These chambers are critical for testing product safety and durability across a wide range of industries, from automotive to electronics, pharmaceuticals to materials science.

Features & Capabilities

  • Temperature Range: -70°C to +180°C
  • Humidity Range: 10% to 98% RH (Relative Humidity)
  • Testing Options:
    • Stability tests
    • Rapid temperature change tests
    • Corrosion testing
    • Climatic cycling
  • Applications:
    • Testing of materials and products under extreme environmental conditions.

Relevant Standards

  • IEC 60068 (60068-2-1, 60068-2-2, 60068-2-30)
  • IEC 61300
  • EN 60068
  • EN 60529
  • UL 94
  • UL 746C
  • TSE EN 60068
  • TSE EN ISO 6270
  • TS EN 50581

Custom Design

The design of the climatic test chambers is tailored to each user’s needs for material and test safety.

Standard reference

Climatic test chambers condition specimens to controlled temperature and humidity in line with IEC 60068-2 environmental test methods — for example IEC 60068-2-1 (Cold), 60068-2-2 (Dry heat), 60068-2-78 (Damp heat, steady state) and 60068-2-30 (Damp heat, cyclic). The set points, dwell times and cycle profile are selected from the relevant test specification.

/ 01

Standards
& methods.

Reach-In Chambers
StandardReference
IEC 60068-2Environmental Testing — Tests
/ 02

Datasheets.

Beyond the catalogue

ULMEKA engineers test systems
to specification.

If your requirement is outside this catalogue — custom chamber sizes, combined-standard integration, or tailored test profiles — talk to our engineering team.

Talk to an engineer