{"id":10825,"date":"2025-01-27T14:55:37","date_gmt":"2025-01-27T11:55:37","guid":{"rendered":"https:\/\/ulmeka.com\/?p=10825"},"modified":"2025-02-14T12:29:13","modified_gmt":"2025-02-14T09:29:13","slug":"en-60598-1-standard-and-test-equipment","status":"publish","type":"post","link":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/","title":{"rendered":"EN 60598-1 Standard and Test Equipment"},"content":{"rendered":"<p><strong><a href=\"https:\/\/ulmeka.com\/urun-kategori\/standartlar\/en-60598-iec-60598\/\">EN 60598-1<\/a>, Luminaires \u2013 Part 1: General requirements and tests<\/strong> is the standard that defines the general safety requirements and test methods for lighting fixtures. This standard is the European Union-adopted version of IEC <a href=\"https:\/\/ulmeka.com\/urun-kategori\/standartlar\/en-60598-iec-60598\/\">60598-1<\/a> and is applied to ensure the safety of all lighting equipment.<\/p><h2 class=\"wp-block-heading\"><strong>Content<\/strong><\/h2><p>This standard defines the safety features and performance requirements for the following lighting devices:<\/p><ul class=\"wp-block-list\"><li><strong>Fixed Luminaires<\/strong> Devices mounted on fixed surfaces such as walls, ceilings, or floors.<\/li>\n\n<li><strong>Portable Luminaires<\/strong><\/li>\n\n<li><strong>Decorative Luminaires<\/strong> Chandeliers, sconces, etc.<\/li>\n\n<li><strong>Luminaires with Built-in Power Supply<\/strong> Devices with integrated power systems, such as LED-driver luminaires.<\/li>\n\n<li><strong>Outdoor Luminaires<\/strong> Devices that are dust- and water-resistant, typically with IP65 or higher protection ratings.<\/li>\n\n<li><strong>Emergency Lighting Systems<\/strong> Safety and emergency lights used during power outages.<\/li><\/ul><h2 class=\"wp-block-heading\"><strong>Tests Included in the Standard<\/strong><\/h2><p><a href=\"https:\/\/ulmeka.com\/urun-kategori\/standartlar\/en-60598-iec-60598\/\">EN 60598-1<\/a> includes various testing procedures to assess whether devices are compliant with safety standards:<\/p><ul class=\"wp-block-list\"><li><strong>Mechanical Durability Tests<\/strong> The device&#8217;s resistance to physical shocks and vibrations.<\/li>\n\n<li><strong>Thermal Tests<\/strong> Resistance to heat and evaluation of overheating situations.<\/li>\n\n<li><strong>Electrical Tests<\/strong> Grounding, insulation, and short circuit tests.<\/li>\n\n<li><strong>IP Code Tests<\/strong> The degree of protection against dust, water, and external factors.<\/li>\n\n<li><strong>Photometric Tests<\/strong> Light distribution and performance measurements.<\/li>\n\n<li><strong>Fire Risk Assessment<\/strong> Protection against fire hazards that could arise from overheating or electrical failures.<\/li><\/ul><h2 class=\"wp-block-heading\"><strong>Types of Devices Covered in the Standard<\/strong><\/h2><p>Since EN 60598-1 defines the basic safety rules for all types of lighting fixtures, the following devices fall within the scope of this standard:<\/p><ul class=\"wp-block-list\"><li>LED lamps and luminaires.<\/li>\n\n<li>Fluorescent lamps.<\/li>\n\n<li>Halogen lamps.<\/li>\n\n<li>Energy-efficient lamps.<\/li>\n\n<li>Solar-powered lamps.<\/li>\n\n<li>Industrial lighting systems.<\/li>\n\n<li>Outdoor projectors and decorative lighting fixtures.<\/li><\/ul><div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"658\" src=\"https:\/\/ulmeka.com\/wp-content\/uploads\/2023\/09\/IP-X3-X4-X9K-e1696081712559.jpeg\" alt=\"\" class=\"wp-image-10438\" srcset=\"https:\/\/ulmeka.com\/wp-content\/uploads\/2023\/09\/IP-X3-X4-X9K-e1696081712559.jpeg 1000w, https:\/\/ulmeka.com\/wp-content\/uploads\/2023\/09\/IP-X3-X4-X9K-e1696081712559-150x99.jpeg 150w, https:\/\/ulmeka.com\/wp-content\/uploads\/2023\/09\/IP-X3-X4-X9K-e1696081712559-300x197.jpeg 300w, https:\/\/ulmeka.com\/wp-content\/uploads\/2023\/09\/IP-X3-X4-X9K-e1696081712559-768x505.jpeg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><h2 class=\"wp-block-heading\"><strong>Test Devices for EN 60598-1 Standard<\/strong><\/h2><p>The IP tests in EN 60598-1 check whether the devices are compliant with the Ingress Protection (IP) rating. The devices used to perform these tests are listed below:<\/p><ol class=\"wp-block-list\"><li><strong><a href=\"https:\/\/ulmeka.com\/urun\/jet-nozzle-ipx5-ipx6\/\">Dust and Solid Object Protection Test Devices (First digit: 0-6)<\/a><\/strong><ul class=\"wp-block-list\"><li><strong>Dust Test Cabinet<\/strong> Valid for IP5X and IP6X levels. The device is exposed to standardized dust particles to test its resistance to dust.Inside the cabinet:<ul><li>Controlled airflow.<\/li><li>Standard dust (e.g., talc or cement dust).<\/li><\/ul>Example: Dust cabinets compliant with IEC 60529.<\/li>\n\n<li><strong>Small Solid Object Entry Test Probes<\/strong> Special test probe sets:<ul><li>\u00d850 mm sphere (for IP1X).\u00d812.5 mm, \u00d82.5 mm, and \u00d81 mm test probes (for IP2X, IP3X, and IP4X).<\/li><\/ul>Used to confirm that solid objects cannot enter the enclosure.<\/li><\/ul><\/li>\n\n<li><strong><a href=\"https:\/\/ulmeka.com\/urun\/ipx3-ipx4-ipx9k-test-kabini\/\">Liquid Protection Test Devices (Second digit: 0-9)<\/a><\/strong><ul class=\"wp-block-list\"><li><strong>Drip Test Device<\/strong> (for IPX1 and IPX2) The fixture is tested under a controlled dripping mechanism.<ul class=\"wp-block-list\"><li>Drip device: Drops water evenly from holes with a diameter of 1 mm.<\/li>\n\n<li>Can be tested at angles of 15\u00b0.<\/li><\/ul><\/li>\n\n<li><a href=\"https:\/\/ulmeka.com\/urun\/spray-nozzle-ipx3-ipx4\/\"><strong>Spray Test Device<\/strong> (for IPX3 and IPX4) <\/a><\/li>\n\n<li>Testing is done using a spray rod or rotating pipe.<ul class=\"wp-block-list\"><li>Key equipment: Water spray pipes with holes placed between 120\u00b0 and 180\u00b0.<\/li>\n\n<li>Adjustments for different pressure and flow rates.<\/li><\/ul><\/li>\n\n<li><a href=\"https:\/\/ulmeka.com\/urun\/jet-nozzle-ipx5-ipx6\/\"><strong>High-Pressure Water Test<\/strong> (for IPX5 and IPX6) <\/a><\/li>\n\n<li>A water jet nozzle is used.<ul class=\"wp-block-list\"><li>Key parameters:<ul class=\"wp-block-list\"><li>Nozzle diameter: 6.3 mm (IPX5) and 12.5 mm (IPX6).<\/li>\n\n<li>Pressure: 30 kPa &#8211; 100 kPa.<\/li>\n\n<li>Water flow: 12.5 liters\/minute (IPX5) and 100 liters\/minute (IPX6).<\/li><\/ul><\/li><\/ul><\/li>\n\n<li><a href=\"https:\/\/ulmeka.com\/urun\/ipx3-ipx4-ipx9k-test-kabini\/\"><strong>Water Immersion Test Device<\/strong> (for IPX7 and IPX8) Test tanks<\/a><\/li>\n\n<li><ul><li>The device is immersed in water for testing.Depth and time are controlled (e.g., 1 meter depth for 30 minutes).<\/li><\/ul>Special requirements for IPX8:<ul class=\"wp-block-list\"><li>Special pressurized tanks.<\/li><\/ul><\/li>\n\n<li><a href=\"https:\/\/ulmeka.com\/urun\/ipx3-ipx4-ipx9k-test-kabini\/\"><strong>Vapor and Humidity Test Cabinets<\/strong> (for IPX9) <\/a><\/li>\n\n<li>High-pressure and high-temperature water spray devices.<ul class=\"wp-block-list\"><li>Tests: Water spray at 80\u00b0C.<\/li><\/ul><\/li><\/ul><\/li>\n\n<li><strong>Control and Monitoring Equipment<\/strong><ul class=\"wp-block-list\"><li>Water pressure and flow measurement devices: To check nozzle output.<\/li>\n\n<li>Precision timers: For accurate control of test durations.<\/li>\n\n<li>Humidity and temperature sensors: For monitoring environmental conditions.<\/li>\n\n<li>Data recorders and cameras: To capture data during testing.<\/li><\/ul><\/li><\/ol><p><strong>Laboratory Setup Considerations<\/strong><\/p><ul class=\"wp-block-list\"><li>All devices must comply with IEC 60529 and EN 60598-1 standards.<\/li>\n\n<li>Test devices should be regularly calibrated.<\/li>\n\n<li>Tested equipment should be evaluated in accordance with its IP protection rating.<\/li><\/ul><p>At <strong><a href=\"http:\/\/ulmeka.com\">ULMEKA Mekatronik Engineering Ltd.<\/a><\/strong>, we are dedicated to carefully and meticulously producing test devices in compliance with the <a href=\"https:\/\/ulmeka.com\/urun-kategori\/standartlar\/en-60598-iec-60598\/\">EN 60598-1<\/a> standard and other IP test devices tailored to your specific needs. You can <a href=\"mailto: info@ulmeka.com\">contact us<\/a> for custom-sized test devices and machine automation systems that meet your requirements.<\/p><p><\/p>","protected":false},"excerpt":{"rendered":"<p>EN 60598-1, Luminaires \u2013 Part 1: General requirements and tests is the standard that defines the general safety requirements and<\/p>\n","protected":false},"author":3,"featured_media":12112,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[220],"tags":[],"class_list":["post-10825","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>EN 60598-1 Standard and Test Equipment - Ulmeka Mechatronics<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"EN 60598-1 Standard and Test Equipment - Ulmeka Mechatronics\" \/>\n<meta property=\"og:description\" content=\"EN 60598-1, Luminaires \u2013 Part 1: General requirements and tests is the standard that defines the general safety requirements and\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/\" \/>\n<meta property=\"og:site_name\" content=\"Ulmeka Mechatronics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ulmekamekatronik\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-27T11:55:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-14T09:29:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"844\" \/>\n\t<meta property=\"og:image:height\" content=\"844\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"ulmeka\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"ulmeka\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/\"},\"author\":{\"name\":\"ulmeka\",\"@id\":\"https:\/\/ulmeka.com\/en\/#\/schema\/person\/5df4fcc1738d5b717a68b0ed9bc5b8a9\"},\"headline\":\"EN 60598-1 Standard and Test Equipment\",\"datePublished\":\"2025-01-27T11:55:37+00:00\",\"dateModified\":\"2025-02-14T09:29:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/\"},\"wordCount\":670,\"publisher\":{\"@id\":\"https:\/\/ulmeka.com\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp\",\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/\",\"url\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/\",\"name\":\"EN 60598-1 Standard and Test Equipment - Ulmeka Mechatronics\",\"isPartOf\":{\"@id\":\"https:\/\/ulmeka.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp\",\"datePublished\":\"2025-01-27T11:55:37+00:00\",\"dateModified\":\"2025-02-14T09:29:13+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#primaryimage\",\"url\":\"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp\",\"contentUrl\":\"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp\",\"width\":844,\"height\":844},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Homepage\",\"item\":\"https:\/\/ulmeka.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"EN 60598-1 Standard and Test Equipment\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ulmeka.com\/en\/#website\",\"url\":\"https:\/\/ulmeka.com\/en\/\",\"name\":\"Ulmeka Mekatronik - Test Cihazlar\u0131\",\"description\":\"Test Makinalar\u0131 - \u00d6zel Makina \u0130malat\u0131 - Otomasyon - Yaz\u0131l\u0131m - Makina Otomasyonu\",\"publisher\":{\"@id\":\"https:\/\/ulmeka.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ulmeka.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/ulmeka.com\/en\/#organization\",\"name\":\"Ulmeka Mechatronics - Test Equipment\",\"url\":\"https:\/\/ulmeka.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ulmeka.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/ulmeka.com\/wp-content\/uploads\/2023\/09\/ulmeka-logo.webp\",\"contentUrl\":\"https:\/\/ulmeka.com\/wp-content\/uploads\/2023\/09\/ulmeka-logo.webp\",\"width\":1427,\"height\":385,\"caption\":\"Ulmeka Mechatronics - Test Equipment\"},\"image\":{\"@id\":\"https:\/\/ulmeka.com\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/ulmekamekatronik\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/ulmeka.com\/en\/#\/schema\/person\/5df4fcc1738d5b717a68b0ed9bc5b8a9\",\"name\":\"ulmeka\",\"url\":\"https:\/\/ulmeka.com\/en\/author\/ulmeka\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"EN 60598-1 Standard and Test Equipment - Ulmeka Mechatronics","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/","og_locale":"en_US","og_type":"article","og_title":"EN 60598-1 Standard and Test Equipment - Ulmeka Mechatronics","og_description":"EN 60598-1, Luminaires \u2013 Part 1: General requirements and tests is the standard that defines the general safety requirements and","og_url":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/","og_site_name":"Ulmeka Mechatronics","article_publisher":"https:\/\/www.facebook.com\/ulmekamekatronik","article_published_time":"2025-01-27T11:55:37+00:00","article_modified_time":"2025-02-14T09:29:13+00:00","og_image":[{"width":844,"height":844,"url":"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp","type":"image\/webp"}],"author":"ulmeka","twitter_card":"summary_large_image","twitter_misc":{"Written by":"ulmeka","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#article","isPartOf":{"@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/"},"author":{"name":"ulmeka","@id":"https:\/\/ulmeka.com\/en\/#\/schema\/person\/5df4fcc1738d5b717a68b0ed9bc5b8a9"},"headline":"EN 60598-1 Standard and Test Equipment","datePublished":"2025-01-27T11:55:37+00:00","dateModified":"2025-02-14T09:29:13+00:00","mainEntityOfPage":{"@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/"},"wordCount":670,"publisher":{"@id":"https:\/\/ulmeka.com\/en\/#organization"},"image":{"@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#primaryimage"},"thumbnailUrl":"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp","inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/","url":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/","name":"EN 60598-1 Standard and Test Equipment - Ulmeka Mechatronics","isPartOf":{"@id":"https:\/\/ulmeka.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#primaryimage"},"image":{"@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#primaryimage"},"thumbnailUrl":"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp","datePublished":"2025-01-27T11:55:37+00:00","dateModified":"2025-02-14T09:29:13+00:00","breadcrumb":{"@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#primaryimage","url":"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp","contentUrl":"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp","width":844,"height":844},{"@type":"BreadcrumbList","@id":"https:\/\/ulmeka.com\/en\/en-60598-1-standard-and-test-equipment\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Homepage","item":"https:\/\/ulmeka.com\/en\/"},{"@type":"ListItem","position":2,"name":"EN 60598-1 Standard and Test Equipment"}]},{"@type":"WebSite","@id":"https:\/\/ulmeka.com\/en\/#website","url":"https:\/\/ulmeka.com\/en\/","name":"Ulmeka Mekatronik - Test Cihazlar\u0131","description":"Test Makinalar\u0131 - \u00d6zel Makina \u0130malat\u0131 - Otomasyon - Yaz\u0131l\u0131m - Makina Otomasyonu","publisher":{"@id":"https:\/\/ulmeka.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ulmeka.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ulmeka.com\/en\/#organization","name":"Ulmeka Mechatronics - Test Equipment","url":"https:\/\/ulmeka.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ulmeka.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/ulmeka.com\/wp-content\/uploads\/2023\/09\/ulmeka-logo.webp","contentUrl":"https:\/\/ulmeka.com\/wp-content\/uploads\/2023\/09\/ulmeka-logo.webp","width":1427,"height":385,"caption":"Ulmeka Mechatronics - Test Equipment"},"image":{"@id":"https:\/\/ulmeka.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ulmekamekatronik"]},{"@type":"Person","@id":"https:\/\/ulmeka.com\/en\/#\/schema\/person\/5df4fcc1738d5b717a68b0ed9bc5b8a9","name":"ulmeka","url":"https:\/\/ulmeka.com\/en\/author\/ulmeka\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/ulmeka.com\/wp-content\/uploads\/2025\/01\/iec-60068-walkin-chamber.webp","_links":{"self":[{"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/posts\/10825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/comments?post=10825"}],"version-history":[{"count":5,"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/posts\/10825\/revisions"}],"predecessor-version":[{"id":11184,"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/posts\/10825\/revisions\/11184"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/media\/12112"}],"wp:attachment":[{"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/media?parent=10825"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/categories?post=10825"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ulmeka.com\/en\/wp-json\/wp\/v2\/tags?post=10825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}